Checking suitability of bridge for abnormal vehicles on route to wind farm.
Bridge assesment on A839 and A836.
Assesments on various bridges carried out by Wallace Stone.

STRATHOYKEL WIND FARM BRIDGE ASSESSMENTS

PROJECT DESCRIPTION

Inspection and assessment of bridges on A839 and A836 access route for wind farm for abnormal vehicles.

 

 

Client E.On Climate & Renewables

Completion 2013

Value N/A

AREAS OF RESPONSIBILITY

Inspection; AIP and acceptance by Local Authority; Assessment; checking in accordance with AIP; Reporting.

 

 

 

 

 

  • 4 single span masonry arches
  • 1 two span (14.3m) masonry arch – Listed Structure
  • 1 reinforced concrete arch (16.8m)
  • 1 Bailey type panel bridge (39.6m)

PRINCIPAL ELEMENTS

KEY FEATURES

Assessment for abnormal loads, including checking for standard highway vehicles representing general construction traffic.

 

 

 

 

 

CONTRACTORS

Project Manager - Wallace Stone

 

Copyright © 1973- Wallace Stone
Wallace Stone is a member of the Association for Consultancy and Engineering.
Wallace Stone is a BM TRADA accredited company.